2. Using a punch, knock the float axis out of the bracket hole on the cover.

3. Remove the axle and the float together with the needle valve.

4. Using a 10 mm wrench, unscrew the needle valve seat.

5. Install a new needle valve with a seat and a float.
6. Check and, if necessary, adjust the fuel level in the float chamber (see "Fuel level in the float chamber - checking and adjustment").
7. Install the cover and the remaining removed parts in reverse order.