Removing
1. Partially drain the coolant (see "Coolant - replacement"), or with a pear we select the coolant from the tank.
2. Disconnect the wiring harness from the coolant level sensor (see "Sensor of insufficient coolant level in the expansion tank - check and replace").
3. Key by 10 mm unscrew the coupling bolt of the adsorber mounting bracket. We remove the adsorber from the bracket and, without disconnecting the hoses from it, set it aside.
4. Loosen the clamp with pliers and disconnect the engine radiator steam outlet hose from the tank.
5. Loosen the clamp, disconnect the expansion tank hose from the pipe.
6. Disconnect the tank fastening belt.
7. Remove the expansion tank.
Installation
1. Install the tank in reverse order.
2. Fill the engine cooling system with liquid through the expansion tank (see "Coolant - replacement"), after which we make sure that there is no leakage of liquid at the joints. Tighten the hose clamps if necessary.
3. We start the engine and let it run for several minutes at a crankshaft speed of 2000-3000 rpm to remove air from the cooling system.
4. Turn off the engine and check the coolant level in the expansion tank. If necessary, bring the level of liquid in the tank to normal.