Relay winding (with the generator running) is under the rectified phase voltage of the generator and the relay contacts are open. If the voltage between the clamp «30» generator and «weight» is 13.8–14.5 V, the rectified phase voltage is 5–7 V.
Data for verification
Trip voltage contacts*, V | 5,3 ± 0,4 |
Closing voltage contacts*, V | 0,2 – 1,5 |
winding resistance relay at 20°С, Ohm | 29 + 2 |
* At a temperature (25±5) °C.