- Rated power, kW - 1.3
- Consumed current at rated power, A - 290±10
- Consumed current in the inhibited state, no more than, A - 550
- Current consumption at idle without relay, no more than, A — 60
Starter type 35.3708 is a mixed-excitation DC motor with an electromagnetic two-winding traction relay.
In building 17 (pic. 7-13) four poles 18 are fixed with excitation windings, three of which are serial and one parallel. The body together with covers 6 and 15 is tightened with two bolts. The anchor has an end collector. The armature shaft rotates in ceramic-metal bushings 14 pressed into covers 6 and 15.
Pic. 7-13. Starter 35.3708:
1 - drive gear; 2 - overrunning clutch; 3 - driving ring; 4 - rubber plug; 5 - drive lever; 6 - cover on the drive side; 7 - relay armature; 8 - relay winding; 9 - contact plate; 10 - relay cover; 11 - contact bolts; 12 - collector; 13 - brush; 14 - armature shaft sleeve; 15 - cover from the side of the collector; 16 - casing; 17 - body; 18 - stator pole; 19 - anchor; 20 - intermediate ring; 21 - restrictive ring.
The starter connection diagram is shown in fig. 7-14. When the starter is turned on, the voltage from the battery through the auxiliary relay 4 type 113.3747-10 is supplied to the windings of the starter traction relay (retractor II and retainer I). After closing the contacts of the traction relay, the retracting winding is turned off.
Pic. 7-14. Starter connection diagram:
1 - starter; 2 - battery; 3 - generator; 4 - starter enable relay; 5 - ignition switch.