Pic. 7-35. Scheme of switching on the cleaner and headlight washer: 1 - right headlight cleaner motor; 2 - relay for turning on cleaners and headlight washer; 3 - relay for switching on the dipped headlights; 4 - switch for cleaners and headlight washer; 5 - windshield washer switch; 6 - headlight switch; 7 - outdoor lighting switch; 8 - battery; 9 - generator; 10 - ignition switch; 11 - additional fuse box; 12 - main fuse box; 13 - headlight washer motor, 14 - left headlight cleaner motor
The headlight cleaner motor together with the gearbox is located in the same housing. The design of the cleaner motor is non-separable and in the event of a malfunction it must be replaced with a new one.
Data for checking the headlight cleaner motor
- Rated voltage, V - 12
- Current consumption* at 0.49 Nm (0.05 kgf·m), no more, A - 1.5
- Number* of double shaft strokes per minute at 0.49 Nm (0.05 kgf·m) — 50±5
- Output shaft swing angle — 65°±1°30
* At a voltage of 12 V and a temperature of 25±10°С