Hydraulic tensioner installed at the front of the cylinder head (on the right side) under the outlet pipe of the cooling jacket.
Special split wrench «on 10» (encompassing five faces), unscrew the fitting of the oil supply pipe to the hydraulic tensioner (for clarity, the hoses of the outlet pipe of the cooling jacket are disconnected).
We remove the tube from the tensioner.
head «on 10» unscrew the two nuts securing the tensioner to the cylinder head..
... and take out the tensioner.
Remove the sealing gasket.
To remove the oil supply line to the hydraulic tensioner..
... with a split wrench «on 10» unscrew the tubing..
...and take her away.
ring wrench «at 21» unscrew the fitting of the cylinder block..
... and remove the fitting and pipe with sealing copper washers.
Install the hydraulic camshaft drive chain tensioner and its tube in reverse order. We replace the sealing gasket of the hydraulic tensioner with a new one.